Use case
Electronics traceability labels: boards, reels, trays and enclosures
Electronics makers mark circuit boards, reels and trays of components and finished enclosures with a serial number, a lot and a revision, so a unit can be matched to its records later. This page covers what such a label carries, what EIGP 114 and the public contents page of IPC-1782B say about it, how the data reaches the printer and where BarcoderX stops. The labels are small, so the data usually sits in a Data Matrix, with the same values as text beside it. Your customer's own requirements decide the final label.
The label at a glance
The numbers in the drawing match the list. Sample data is made up. Gray references point to the sources listed at the end of the page.
The documents cited below are the authority on what they cover; this page summarizes, in our own words, the parts we read. BarcoderX prints the label from the data it is given. It does not issue serial numbers, track boards, read or grade barcodes, or certify a label under any rule.
- Data Matrix symbolThe serial, and the lot and revision when your customer wants them, as one 2D symbol, in the message structure your customer specifies. More data in a small area.
- Serial in textThe same serial as human-readable text, for the person who has no scanner or whose scan fails.
- Part and revisionThe part number and the revision, as text.
- Lot and dateThe lot and a date, as text.
- Linear barcodeA Code 128 or Code 39 barcode beside the 2D symbol, for a reader that reads only linear codes. EIGP 114 requires it except in its 2D-only formats. EIGP 114 pp. 11, 34
What EIGP 114 and the IPC-1782B contents page say
ECIA, the electronic components industry association, publishes EIGP 114.2018, a labeling specification for product and shipment identification in the electronics industry (revision of June 20, 2018). It states its purpose as providing technical information for the identification needs of the electronic components industry and the end customer, with recommendations on symbology, dimensions, print quality, standardized sets of data, data identifiers and barcode placement at each level of labeling in the component supply chain. EIGP 114 p. 6 It says it was written with ECIA distributors and refines the use of ANSI MH10 data identifiers. EIGP 114 p. 6
Its scope is component packaging and shipments, and its labels are a product label, an intermediate label, a logistic (carton) label and a packing slip. EIGP 114 pp. 6, 7 It approves two 2D symbologies, Data Matrix ECC 200 and PDF417, and two linear ones, Code 128 and Code 39. EIGP 114 pp. 11, 12 It requires both 2D and linear barcodes, with human-readable text for each data element, because not every trading partner can read the 2D code alone, and it shows 2D-only formats as examples in Appendix D. EIGP 114 pp. 11, 34
A product label goes on the smallest level of packaging, such as a reel. EIGP 114 pp. 13, 14 For it the document requires the supplier part number (data identifier 1P), the quantity (Q), the date code (9D or 10D, in year-and-week form), the lot code (1T, up to 20 characters) and the country of origin (4L), each in the barcode and as text. It calls the serial number (S) and the revision number (2P) optional, to be used as required or when applicable; for the revision, Appendix A.1 lists text only. EIGP 114 pp. 7 to 10, 23 It defines the lot code as a number assigned to a batch or group of items, the serial number as a unique value assigned to each part by the manufacturer, and the revision as a string that tells one closely related design variation from another. EIGP 114 pp. 8, 9, 23 Where no lot or date code is used, the field holds N/T, meaning not traceable by that field. EIGP 114 p. 8
The 2D symbol holds a message in the Format 06 structure of ISO/IEC 15434: a header, a data stream in which each element is a data identifier and its data, separated by a control character, and a trailer. EIGP 114 pp. 29, 30 We did not read ISO/IEC 15434, and this page does not describe it. Your customer's specification says which structure to use.
For placement, the document's examples put a reel label on a flat surface of the reel, clear of the center spindle hole and any cutouts. It also says that where a label must be wrapped to fit, the 2D symbol is not wrapped over an edge: the whole symbol goes on a flat surface. EIGP 114 p. 36
It also sets minimum symbol dimensions and a minimum print-quality grade. EIGP 114 pp. 27, 32 This page repeats none of those figures: the document is the authority, and BarcoderX does not read or grade codes. The document's notice says each company must decide for itself whether to follow its guidelines, EIGP 114 p. 2 and it says the format requirements of each distributor may vary. EIGP 114 p. 13 So your customer's own labeling requirements decide the final label.
IPC publishes IPC-1782B, "Standard for Manufacturing and Supply Chain Traceability of Electronic Products" (September 2023). Its public contents and scope page say it covers manufacturing and supply chain traceability for printed board assemblies, mechanical assembly and printed board fabrication, both inside the plant and between locations, with four levels of traceability for materials and processes. IPC-1782B p. 1 Its contents list headings for a unique printed board marking traceability cell (5.5.2.1), an individual material traceability cell (5.4.2) and a labeling traceability cell (5.5.2.26), and define terms such as lot number, date code, serial number and unique assembly ID. IPC-1782B contents, 1.6, 5.4, 5.5 We read only that public contents and scope page, not the standard, and this page states no requirement from it.
EIGP 114 gives no layout for a label on a circuit board or an enclosure, and the IPC-1782B pages we read give none, so this page gives none: that layout comes from your customer and your own procedures.
Boards, reels, trays and enclosures
| Carrier | What it usually carries | What the sources say |
|---|---|---|
| Circuit board | A serial number, often with a lot and a revision: a small Data Matrix with the serial as text beside it. | IPC-1782B's contents list a heading for unique printed board marking; we did not read its body. IPC-1782B 5.5.2.1 Marking a board directly, rather than with a label, is outside this page. |
| Reel | Part number, quantity, lot, date code and country of origin; serial and revision when used. | EIGP 114 requires these fields, including country of origin, on a product label and puts the label on a flat surface of the reel. EIGP 114 pp. 8, 10, 23, 36 |
| Tray, tube or bag | The same fields as a reel label: part number, quantity, lot, date code and country of origin; serial and revision when used. | The placement examples we could read name reels, bags and tubes. We found no tray example, so follow your customer's instruction for a tray. EIGP 114 pp. 13, 36 |
| Enclosure or finished unit | The serial of the finished unit, with the model and revision. | EIGP 114 does not cover it; IPC-1782B's scope includes mechanical assembly, and we did not read its body. Safety and conformity marks are a legal matter for the manufacturer and this page does not cover them. For a serial label on a finished product, see manufacturing labels. |
Which barcodes, and why
BarcoderX does not read barcodes, so scanning a board or a reel is your scanner and your software. The symbology follows your customer and the readers you run.
| Barcode | Why it is on the label | Edition |
|---|---|---|
| Data Matrix | A 2D symbol holds more data in a small area and carries error correction. EIGP 114 names Data Matrix ECC 200. EIGP 114 p. 11 The data is the string your customer specifies. | Ultimate |
| GS1 Data Matrix | Data Matrix with the GS1 rules on top, including FNC1 and Application Identifiers. Use it when your customer asks for GS1-structured data, such as a GTIN with a lot or a serial number. BarcoderX validates each Application Identifier and computes the check digits. | Ultimate |
| Code 128 or Code 39 | A linear barcode, which EIGP 114 requires beside the 2D symbol except in its 2D-only formats, and which serves a reader that reads only linear codes. It names Code 128 and Code 39. EIGP 114 pp. 11, 12, 34 | Basic |
| PDF417 | EIGP 114 names PDF417 as its other 2D symbology. EIGP 114 p. 11 | Ultimate |
BarcoderX enforces quiet zones, snaps the module width to whole dots and reports the effective size. On a small symbol that matters: the module can only be a whole number of printer dots, so read the reported size instead of assuming the one you asked for, and test the result with your own readers, printers and media. This page gives no size or resolution figure, because BarcoderX publishes none. Symbol options The symbology registry
The data that fills it
| Field | Sample value | Where it goes |
|---|---|---|
| Part number | PCB-4417 | Text, element 3, and in the symbol if your customer's message includes it. |
| Revision | C | Text, element 3, and in the symbol. |
| Serial number | SN-000731 | The symbol, element 1, and the text beside it, element 2. |
| Lot | 26A-114 | Text, element 4, and in the symbol. |
| Date | 2026-11-14 | Text, element 4. A date in the symbol follows your customer's format. |
| Quantity (reel or tray) | 2,500 | Text and symbol on a reel or tray label. |
The values live in your ERP, your manufacturing execution system (MES) or your test system. The label prints when something happens there: a board passes a test, a reel is received or split, a unit leaves final assembly. Nobody types a serial number into a label, and the rule that a serial is never reused is your system's.
The values come from objects, a DataTable, CSV, JSON or XML. A panel of boards is one record per board in your data. Counters, masks and more than 100 built-in functions produce the values that change on every label. Templates and data
Small labels, small text
A small label leaves little room for text. BarcoderX draws an element with the printer's own command only where the printer profile marks that rendering as equal to the preview, and as a raster image otherwise, so the print matches the preview. Native or raster printing
Part descriptions with accents, such as ñ, á or ü, need a font that holds them and a character set the printer reads. Fonts and accents Inside a 2D symbol, accented text can declare its character set with ECI where the symbology allows one.
Why generate it from code
A customer's label format is a template: its fields, its symbol and its message structure. A second customer asks for another. One template per format, driven by code and data from your own systems, keeps each one right, and the label appears when the event fires, with the right record, at the right printer and with no one at a keyboard. That is server-side printing: a service builds the label and sends it to a printer, with nobody signed in, no browser open and no print dialog. Server-side label printing
How it reaches the printer
The printer commands are the same on both routes, and both run on infrastructure you operate.
- Direct, from your application. The SDK packages send the printer commands from your own .NET process over TCP port 9100, serial, the Windows spooler, CUPS or USB. No API server and no agent is in the path.
- Through your API server. Your application queues a print job through the REST API on your API server. A print agent on the printer's network collects it and writes it to the printer beside it. The agent only dials out, so the printer network needs no inbound port.
A board label prints when a board is built or passes a test, a reel label when a reel is received or split, an enclosure label at final assembly; your own application starts the print.
Delivery to the agent is at-least-once and the agent de-duplicates by job id, so a reconnect does not print a label twice. Print jobs honor an idempotency key, so a retried request does not queue a second label.
Media is the media maker's call. Whether a label stock and its adhesive survive soldering, washing, cleaning, static control or the heat and chemicals of your process is stated by the maker of the media. BarcoderX makes no statement about it, and neither does this page. Test the stock and ribbon where the label will live. How the two thermal methods differ is in direct thermal and thermal transfer.
Which edition covers it
EditionsBasic covers the linear (1D) and postal symbologies, including every GS1 DataBar variant; Ultimate adds the PDF417 family, other multi-row symbologies, every matrix (2D) symbology and GS1 composites, as set out on the pricing page.
For these labels, that means Code 128 and Code 39 are in Basic. Data Matrix and GS1 Data Matrix are matrix (2D) symbologies and PDF417 is part of the PDF417 family, so all three need Ultimate.
The ZPL behind it
Printer commands a label like this can use. Each page explains one command in our own words.
What BarcoderX does not do here
- No board tracking. BarcoderX prints a label from the data it is given. It does not follow a board through the line, record which board got which serial or keep a build history. Your ERP, MES or test system does, and it calls the print. BarcoderX is not a manufacturing execution system.
- No reading, verifying or grading. EIGP 114 sets dimensions and print quality. BarcoderX does not read, verify or grade barcodes; measuring a symbol takes separate equipment.
- No serial numbers issued. The serial, and the rule that it is never reused, come from your system.
- No certification. BarcoderX does not check a label against a customer's requirements, EIGP 114 or IPC-1782B, and does not certify, approve or validate a label under any of them. EIGP 114 describes a certification program run with a third party; BarcoderX takes no part in it. EIGP 114 p. 42
- No claim about your process. Whether a label material suits soldering, washing, static control or any other process condition belongs to the media maker.
- No direct marking and no applicators. Marking a board directly, and applying a printed label by machine, are outside this page: nothing here describes controlling a marker or an applicator.
Keep reading
Barcodes: the symbology registry Templates and data Native or raster printing Fonts and accents Glossary Manufacturing labels: work-in-process, kanban and serial Asset tags: identifying equipment, tools and fixed assets Automotive labels: Global Transport Label, JIS ZPL 2D codes: QR Code, Data Matrix, PDF417 Pricing: what each edition covers All use casesNew to the printer language? Read the ZPL guides and command reference.
Sources
- ECIA: EIGP 114.2018, Labeling Specification for Product and Shipment Identification in the Electronics Industry - 2D Barcode (Including Human Readable and 1D Barcode)
- Electronic Components Industry Association, revision of June 20, 2018, published on its Logistics Services page. Read on November 15, 2026, as text; its example label images were not reviewed. Page numbers are those printed in its footer (Page n of 44). Check the current edition before you rely on a detail. https://
www.ecianow.org/ eigp-114-2018-ecia-labeling-specification-for-product-and-shipment-identification-in-the-electronics-industry-2d-barcode/ - ECIA: Logistics Services
- ECIA web page listing EIGP 114.2018 under that title, read November 15, 2026. https://
www.ecianow.org/ logistics-services/ - IPC: IPC-1782B, Standard for Manufacturing and Supply Chain Traceability of Electronic Products (contents and scope)
- IPC, September 2023. Only IPC's public cover, contents and scope page was read, on November 15, 2026. The standard itself was not read. https://
www.electronics.org/ TOC/ IPC-1782B_TOC.pdf
Written by BarcoderX in its own words; not a publication of the bodies named above, whose documents are the authority. What this page says about BarcoderX comes from its published barcodes, pricing, printing, templates and data, fonts and glossary pages. Read on November 15, 2026. Check the current edition before you rely on a detail.