^BQ QR Code Barcode
Prints a QR Code symbol from the data of the next field; the field data must begin with switches that select the error-correction level and the input mode.
^BQa,b,c,d,e
^BQ parameters
| Parameter | Meaning | Accepted values | Default |
|---|---|---|---|
afield orientationpp. 128, 129, 134 |
Orientation of the symbol. The guide lists only normal orientation and says ^BQ does not take its orientation from ^FW.
|
The guide's table lists only the value normal ( |
Not stated in the guide. |
bmodelp. 128 |
Which QR Code model is produced: the original specification or the enhanced one. The guide says model 2 adds features and can be told apart from model 1 automatically, and that it should normally be used. |
|
2
|
cmagnification factorp. 128 |
Size of one module of the symbol, as a multiplier. |
|
Depends on the printer resolution: 1 on 150 dpi, 2 on 200 dpi, 3 on 300 dpi, 6 on 600 dpi. |
derror correctionpp. 128, 129 |
Error-correction level of the symbol. The same four letters are also written in the field data as the error-correction switch. The guide does not say which of the two takes precedence if both are given. |
|
The parameter table says Q if the parameter is empty and M for invalid values. The |
emask valuep. 128 |
Mask pattern number applied to the symbol. The guide gives no further explanation of the mask value. |
|
7
|
^BQ notes and gotchas
-
Gotcha
The data in the field must carry switches in a fixed order. Up to four switch fields are described: an optional mixed-mode switch (starts with D, ends with a comma), a mandatory error-correction letter (H, Q, M or L), a mandatory data-input letter (A or M) followed by a comma, and, only when the input is M, a character-mode switch. The data follows immediately after the last switch.
pp. 129, 130 -
Note
Automatic input (A) layout in normal mode: error-correction letter, the letter A, a comma, then the data. Manual input (M) layout in normal mode: error-correction letter, the letter M, a comma, a character-mode switch, then the data. With A the character mode is not given; with M it must be.
pp. 131, 132 -
Note
Character modes for manual input: N is numeric (digits 0 to 9); A is alphanumeric (digits, upper-case letters, space and the symbols $ % * + - . / :, which the guide counts as 45 characters); B followed by a four-digit count is 8-bit byte data; K is Kanji and every character after K must be 16-bit, so any 8-bit character causes an error.
pp. 130, 131 -
Note
With automatic input the binary codes 0x80 to 0x9F and 0xE0 to 0xFF cannot be set in the data.
pp. 130, 131 -
Note
Mixed mode lets several character modes share one symbol. Its switch is the letter D, a two-digit code number from 01 to 16, a two-digit number of divisions from 02 to 16, a two-digit hexadecimal parity value from 00 to FF, and a comma. The guide says the parity value comes from an exclusive-OR over the original input data. In mixed mode the number of data strings can be up to 200.
pp. 129, 130, 133 -
Note
Kanji data written in Unicode with
p. 134^CI28to^CI30needs the JIS.DAT table loaded on the printer and specified. -
Note
The symbol is printed from the data in a following
pp. 128, 1588^FDstring. The guide lists numeric, alphanumeric, 8-bit byte and Kanji data as encodable, and four error-correction levels. The print ratio is listed as fixed.
Where the guide contradicts itself (5)
-
Guide issue
The error-correction default is stated two ways. The parameter table on page 128 reads Q if the parameter is empty and M for invalid values. The switch text on pages 129 to 131 says M is the default level. The guide does not reconcile them. It also calls the error-correction switch mandatory (required) in the same place it marks M as the default, and does the same for the data-input switch: headed required, yet A is marked as its default (pages 129 and 131).
pp. 128 to 131 -
Guide issue
The guide's list of alphanumeric characters on page 130 ends with a closing parenthesis right after the colon and before the count of 45 characters. Digits, upper-case letters, space and the eight symbols $ % * + - . / : already make 45, so with the parenthesis the list would be 46; the guide does not explain it.
p. 130 -
Guide issue
The byte-mode switch is written Bdddd on page 129 and Bxxxx on page 130. Page 130 says the four characters are exactly four decimal digits holding the number of characters; page 131 says the number of data characters is held as two bytes of BCD code.
pp. 129 to 131 -
Guide issue
The mixed-mode layout for automatic input on page 132 starts with the D switch, but the layout for manual input on page 133 leaves it out, although the example string below it starts with D. In that example the parity value in the string is 8F while the explanatory table beside it shows 0x0C. The example on page 134 uses 0C.
pp. 132 to 134 -
Guide issue
The orientation parameter is listed only as normal with no letter and no default, and the guide's own examples either write N or leave the parameter empty.
pp. 128, 129, 134
^BQ example
^XA ^FO40,40^BQN,2,5^FDQA,PART-4471^FS ^XZ
A model 2 QR Code at a magnification of 5. The field data starts with the switches Q (error-correction level) and A (automatic input) followed by a comma, and the text after the comma is the data that is encoded.
Guides that use ^BQ
BarcoderX is a .NET SDK for thermal labels and barcodes. See the barcode types it covers.
Source Zebra, ZPL II, ZBI 2, Set-Get-Do, Mirror, WML Programming Guide, P1134473-11EN Rev A, 2026/07/05, pages 128 to 134, 144, 167, 1588.
Written by BarcoderX in its own words. Checked against the guide on 2026-11-14.