^FS Field Separator
Marks the end of a field definition, so the commands that follow start a new field.
^FS
^FS parameters
This command takes no parameters.
^FS notes and gotchas
-
Interaction
p. 187^FSterminates an^FBcommand. Each text block needs its own^FB. -
Interaction
The guide says correct use of
p. 209^FXincludes following it with^FS. -
Interaction
pp. 269, 293^LHand^JMmust come before the first^FSin a format. -
Note
p. 204^FSdenotes the end of a field definition. It can also be sent as the single ASCII control character SI (control-O, hexadecimal 0F). -
Guide issue
The
pp. 204, 1765 to 1767^FSentry recommends placing^FSafter every command that creates a printable line. The scripting-shortcuts section says^FSis only needed to separate specific fields, calls the^FSafter format commands such as^PR,^LLand^LHunnecessary, and says the shorter script gives the same label. It also says the^FSon the last field can be dropped because^XZdoes the same job. Both statements are recorded here; the two pages do not say which one wins.
^FS example
^XA ^FO40,40^A0N,30,30^FDFirst field^FS ^FO40,90^A0N,30,30^FDSecond field^FS ^XZ
Two fields. The first ^FS ends the first field, so the second ^FO starts a new one. The second ^FS ends the last field before ^XZ.
Guides that use ^FS
BarcoderX is a .NET SDK for thermal labels and barcodes. See how it prints and exports labels.
Source Zebra, ZPL II, ZBI 2, Set-Get-Do, Mirror, WML Programming Guide, P1134473-11EN Rev A, 2026/07/05, pages 60, 187, 190, 201, 204, 209, 269, 293, 370, 375, 1765 to 1767.
Written by BarcoderX in its own words. Checked against the guide on 2026-11-14.
ZPL and ZPL II are trademarks of Zebra Technologies Corporation. This reference is written by BarcoderX in its own words from Zebra's published programming guide. BarcoderX is an independent product and is not affiliated with, endorsed by or sponsored by Zebra Technologies.