Dots, millimeters and dpi

Question What is a dot, and how many dots per millimeter does my printer have?

Every position and size in ZPL is counted in dots, the smallest mark the printhead can make. How big a dot is depends on the printhead, so the same number of dots is a different physical length on different printers.

The guide lists printheads of 6, 8, 12 and 24 dots per millimeter. Think in dots per millimeter: it is how the guide describes the printheads, and the dpi figures it gives for the same head differ from page to page.pp. 210, 294

The guide is not consistent about dpi. For the 8 dots per millimeter head it says 200 dpi in its exercises, 203 in the ^GB entry, and 203.2 dots per inch in the ^LL formulas. For the 12 dots per millimeter head it says 300 dpi, 304 dots per inch in the ^JM entry, 304.8 in the ^LL formulas, and the ^LH entry lists 11.8 dots per millimeter.pp. 49, 210, 269, 293, 294

TipOur rule: use dots per millimeter for planning, and treat any dpi figure as nominal. Your printer's configuration label lists its resolution.p. 49

To convert a size in millimeters to dots, multiply by the dots per millimeter of your printer. A 100 mm wide label is 800 dots across at 8 dots per millimeter and 1200 dots at 12. The same method works for every width, height and thickness in the format.p. 210

Where 0,0 is, and how ^FO measures from it

Question Where is position 0,0, and what is the difference between ^FO and ^FT?

The default home position of a label is its upper-left corner, 0,0. Anything below and to the right of it can print.p. 293

The guide's exercise section words the home position differently, as the left-hand trailing edge of the label as it leaves the printer, with exceptions. The ^LH and ^FO entries are the authoritative description, so follow those.pp. 49, 201, 293

^FO places a field by its upper-left corner: x and y are dots from the label home, each 0 to 32000, default 0. Nothing checks that the result is on the label, so an oversized value can put the field completely off it.p. 201

^FT also positions relative to the label home, but it fixes the typesetting origin to the field's content rather than its upper-left corner. For barcodes the origin is the base of the code, and for boxes and images it is the bottom-left corner with left justification. If you leave x and y out, ^FT continues from the end of the previous text field.pp. 205, 206

WarningPrefer ^FO while you are learning. The guide lists several cases where ^FT without coordinates is not recommended, among them the first field in a format, variable data and fields after serialization.p. 206

With a text block, ^FO grows the block downward as the font gets larger, while ^FT anchors the last line and grows upward, which can push the text past the top of the label.p. 187

^LH moves the reference point itself, which is handy for preprinted labels. It affects only the fields after it, should be one of the first commands in the format, and stays in force until the printer is turned off or another ^LH arrives.p. 293

Both ^FO and ^FT accept a third justification value (left, right or automatic), but only on firmware V60.14.x, V50.14.x or later.pp. 201, 205

example.zplZPL
^XA
^LH24,16
^FO0,0^A0N,30,30^FDHome^FS
^FO200,60^A0N,30,30^FDOffset^FS
^XZ

^LH moves the reference point 24 dots right and 16 down. The first field then starts at that new home, and the second 200 dots right of and 60 dots below it. The new home stays in force until the printer is turned off or another ^LH arrives, so start the next format with ^LH0,0 if it should count from the corner again.

Rotation and field direction

Question How do rotation and field direction change where text lands?

^A takes an orientation of N (normal), R (90 degrees clockwise), I (inverted 180) or B (read from the bottom up, 270). If you leave it out, the last ^FW value applies.pp. 60, 208

^FW sets that default for later fields; it starts at N at power-up and stays until the printer is turned off or a new ^FW arrives. A field with its own orientation keeps it.p. 208

^FO defines its x and y independently of rotation. Where the rotated text then sits also depends on the justification, so work out rotated layouts on a test label.pp. 201, 1606

^FP changes the direction of the field's characters: horizontal, vertical or reverse, with an optional extra gap between characters. It is mainly for Asian fonts.p. 202

The guide has a section of charts showing how rotation, ^FP direction and ^FO or ^FT justification combine for normal, rotated, bottom-up and inverted orientation. Refer to it when a rotated field lands somewhere unexpected.pp. 1606 to 1612

To turn the whole label around instead, ^PO with I inverts the format 180 degrees. It inverts the coordinates too, so a different ^LH can move the output back onto the label. The setting lasts until another ^PO or power-off.p. 322

example.zplZPL
^XA
^FWB
^FO50,50^A0N,30,30^FDNormal^FS
^FO100,200^A0,30,30^FDBottom up^FS
^XZ

After ^FWB the second field, which names no orientation, takes the bottom-up default. The first names N and ignores it. ^FW stays in force until the printer is turned off or another ^FW arrives, so start the next format with ^FWN if it should be back to normal.

Units, and moving a layout to another density

Question Can I use millimeters, and what happens at a different density?

^MU switches the unit of x, y and sizes to dots (D, the default), inches (I) or millimeters (M). It works field by field, carries over until you change it, and belongs at the start of the format.pp. 312, 313

^MU also converts a format between densities. The base value can be 150, 200 or 300 and the target 300 or 600; the guide's examples are 150 to 300, 150 to 600 and 200 to 600. Giving the same value twice turns conversion off.pp. 312, 313

^JM halves the density, for example 12 dots per millimeter becomes 6, and the guide says it doubles the format size and changes where ^FO places fields. It must come before the first ^FS and persists.p. 269

TipA layout written in dots for one head will not match another unless you plan the move: describe sizes in millimeters, or convert with ^MU, before trusting positions.p. 312

To nudge a finished format without editing fields, ^LT moves everything up or down by at most 120 dot rows on most printers, negative toward the top. A large negative value on some models can pull the media back out of the printer.p. 297

example.zplZPL
^XA
^MUm
^FO5,5^GB40,20,1^FS
^XZ

With millimeters selected, a box 40 mm wide and 20 mm tall with a 1 mm border starts 5 mm from the left and top. On an 8 dots per millimeter head that is 40 dots in, 320 dots wide and 160 tall. The unit carries over to later fields, so begin the next format with ^MUd if it counts in dots.

The same label with BarcoderX

Question How does BarcoderX deal with density?

BarcoderX is pre-launch and its API is not final. It is designed to let you describe a label once in .NET and emit ZPL or EPL. It snaps each module width to a whole number of printer dots and reports the effective size.

Questions

Is a 203 dpi printer the same as 8 dots per millimeter?

Nominally yes. The guide uses 200, 203 and 203.2 for that head in different places, which is why dots per millimeter is the safer unit.pp. 49, 210, 294

Where is position 0,0?

At the upper-left corner of the label, unless ^LH has moved the home position.p. 293

Can I use millimeters instead of dots?

Yes. ^MU with M switches coordinates and sizes to millimeters, and ^MU with I to inches.p. 312

Commands in this guide

BarcoderX is a .NET SDK for thermal labels and barcodes. See how it prints and exports labels.

Source Zebra, ZPL II, ZBI 2, Set-Get-Do, Mirror, WML Programming Guide, P1134473-11EN Rev A, 2026/07/05, pages 49, 60, 187, 190, 201, 202, 204 to 206, 208, 210, 269, 293, 294, 297, 312, 313, 322, 1606 to 1612.

Written by BarcoderX in its own words. Checked against the guide on 2026-11-14.

ZPL and ZPL II are trademarks of Zebra Technologies Corporation. This reference is written by BarcoderX in its own words from Zebra's published programming guide. BarcoderX is an independent product and is not affiliated with, endorsed by or sponsored by Zebra Technologies.