^FT Field Typeset
Sets the field position, counted from the label home, using a typesetting origin that stays fixed to the field's contents and does not change with rotation.
^FTx,y,z
^FT parameters
| Parameter | Meaning | Accepted values | Default |
|---|---|---|---|
xx-axis location (in dots)pp. 205, 206 |
Horizontal position of the typesetting origin, counted from the label home position. The guide's general text on page 206 says that when a coordinate is missing, the position following the last formatted field is assumed. |
|
The position after the last formatted text field. |
yy-axis location (in dots)pp. 205, 206 |
Vertical position of the typesetting origin, counted from the label home position. The guide's general text on page 206 says that when a coordinate is missing, the position following the last formatted field is assumed. |
|
The position after the last formatted text field. |
zjustificationpp. 205, 206 |
Whether the typesetting origin refers to the left edge or the right edge of the field, or is chosen automatically from the script of the text. Auto justification may give unexpected results with variable fields or bidirectional text; the guide recommends left or right justification in those cases.FirmwareSupported only in firmware version V60.14.x, V50.14.x or later. |
|
The last accepted |
^FT notes and gotchas
-
Gotcha
The guide lists cases in which
p. 206^FTwithout x and y is not recommended: positioning the first field of a format, any use with^FN, following^SN, variable data, and bidirectional text. -
Interaction
For an
p. 187^FBtext block,^FTuses the baseline origin of the last possible line, so a larger font makes the block grow from bottom to top and the text can print past the top margin. With^FOthe block grows from top to bottom. -
Interaction
The result interacts with the field-direction parameter of
pp. 206, 1606^FPand the rotation parameter of^A. Output examples are in the Field Interactions section. -
Firmware
Right typeset justification is available only on printers with firmware V60.14.x, V50.14.x or later.
Firmware: V60.14.x, V50.14.x or later p. 206 -
Note
The guide notes that
pp. 205, 206^FTis capable of concatenation of fields: a field can be positioned relative to the end of the previous one. -
Note
Where the typesetting origin sits depends on the field type and the justification (guide Table 7). Left justified: for bar codes the base of the barcode at its left edge; for graphic boxes the bottom-left corner of the box; for images the bottom-left corner of the image area. Right justified: the same points on the right side (base of the barcode at its right edge, bottom-right corner of the box, bottom-right corner of the image area). For text the table refers to the Field Interactions examples.
pp. 205, 1606 -
Guide issue
The parameter table on page 205 gives the default for x and y as the position after the last formatted text field, while the text on page 206 says the position following the last formatted field is assumed. The guide does not say whether non-text fields count.
pp. 205, 206
^FT example
^XA ^FT40,100^GB200,60,3^FS ^FT40,160^A0N,30,30^FDShelf 12^FS ^XZ
Two fields positioned with ^FT, both with default (left) justification. The first is a box 200 dots wide and 60 dots high with a 3-dot border, whose origin the guide places at the bottom-left corner. The second is a line of text in the scalable font 0 at 30 dots, with its origin 160 dots down.
Guides that use ^FT
BarcoderX is a .NET SDK for thermal labels and barcodes. See how it prints and exports labels.
Source Zebra, ZPL II, ZBI 2, Set-Get-Do, Mirror, WML Programming Guide, P1134473-11EN Rev A, 2026/07/05, pages 60, 61, 187, 190, 201, 204 to 206, 208, 210, 293, 1606.
Written by BarcoderX in its own words. Checked against the guide on 2026-11-14.
ZPL and ZPL II are trademarks of Zebra Technologies Corporation. This reference is written by BarcoderX in its own words from Zebra's published programming guide. BarcoderX is an independent product and is not affiliated with, endorsed by or sponsored by Zebra Technologies.